One of the biggest challenges of transit temperature monitoring with electronic monitors is getting the data from the device to a computer where it can be viewed and distributed.

Cables, interfaces and software are in the way.
Global Sensors PDF-Logger solves the problem in four simple steps: (1) start logger (2) stop logger (3) plug into USB port (4) get file direct from USB storage.  No software, interfaces or cables.

The PDF-Logger is a logger with a "built-in" USB interface.  The logger creates the file internally and when the unit is stopped, the file is there just like any other file on a USB memory device. 
 Ordering information for Global Sensors PDF-Logger

 

 
 

Call
704-827-4331
PDF-Logger 15 Day Model $19.00 ($17.50 for 40+ units ordered)
Pre-programmed with 2°C to 8°C standard alarm settings
Call
704-827-4331
PDF-Logger 30 Day Model $19.00 ($17.50 for 40+ units ordered)
Pre-programmed with 2°C to 8°C standard alarm settings
Call
704-827-4331
PDF-Logger 60 Day Model $19.00 ($17.50 for 40+ units ordered)
Pre-programmed with 2°C to 8°C standard alarm settings

How Does It Work?

The Global Sensors PDF-Logger is preconfigured in different day models and with different available alarm settings and the option of start delay.   Just order the specific type for your application-no need to use software to set up the logger for recording.  The current standard models are 15 Day, 30 Day and 60 Day.  The current standard alarms are set at "below 2°C" and "above 8°C". 

When you are ready to  use the PDF-Logger, just pull the start tab.  It is easy to break off.  When the tab is removed, the logger begins recording immediately (unless a log delay has been custom-specified).  All LEDs flash in turn for five times When PDF-Logger is started, then the OK light blinks every 10 seconds to confirm proper operation and continued logging.

At destination, or the end of the recording episode, you can observe the LED lights to determine if there has been an "over or under" alarm condition.  The sequence and pattern of the alarm lights provides full information regarding the alarm conditions.  Download our User Manual to see details.

When the PDF-Logger is snapped to stop recording, the USB plug is revealed.  Just stick it into any empty USB port in your computer.

At stopping, the PDF file is immediately created inside the logger, and is ready for copying, moving or opening from the USB flash drive function of the logger.

If you can read a flash drive in your computer, you can read the PDF-Logger with no software installation or other action.  Just plug it in and get the time-temperature record from the device.

You can retain the logger as a permanent record of the temperature conditions.  The PDF file can be read, archived, emailed or used in any way that a file is used in a computer.

To see an example PDF file created by the PDF-Logger, click here.

The PDF file conforms to all aspects of security that are required in regulated usage.  The file cannot by tampered and is encrypted.

A significant aspect of data security is the already downloaded PDF-logger itself.  Since you cannot add files to the drive or remove files, it remains as a secure backup to the data that was collected.

The logger performance is second to none.  It produces an accuracy in the thermal interest zones for cold chain shipping of ±0.3°C...good for any application in the storage or shipment of valuable perishable items.

The graphic details are easy to read and of high quality (click to enlarge):

 

Specifications  User Guide
Usage Cycle   Single use
Temperature Measurement Range -30°C to +70°C (-22°F to +158°F)
Standard Available Durations  7 Day | 30 Day | 60 Day
Temperature Accuracy Range ±0.3°C (±0.6°F) from -20°C to 30°C | ±0.5°C(±0.9°F) outside of this range
Temperature Resolution 0.1°C/°F
Data Storage Capacity 3,800 readings
Recording Duration 1 hour to 60 days option
Shelf Life One year at room temperature; longer with cool storage
Data Sampling Interval 10 seconds to 60 minutes option (depends upon model)
Dimensions 80mm L× 52mm W x 4mm H
Water and Dust Resistance IP65
Weight 16.5g
Data Report Format F Secure Adobe® PDF - Click here for example
Certifications  CE, RoHS
Indicator Light Flashing 'Active' indicator | Flashing 'Alert' indicator
Custom Configurations 6 weeks lead time | Minimum order quantity 500 units | Interval | High and Low Alarms | Log Delay